I. Principle of UV DOAS

Pollutants such as SO₂, NO and NO₂ have obvious, narrow characteristic absorption structures in the 200–430 nm UV band. DOAS splits the absorption spectrum into two parts:

  • Slow-varying part:Caused by Rayleigh scattering, Mie scattering, dust attenuation, varying slowly with wavelength
  • Fast-varying part:Caused by target gas characteristic absorption, oscillating rapidly with wavelength

By mathematically high-pass filtering the spectrum, DOAS "peels" the target gas's narrow-band absorption from the broad-band background interference, then fits it against standard cross-sections by least squares to retrieve concentration. This differential idea makes the measurement almost immune to water vapor, dust and other broad-band interference.

II. Why ultra-low emission needs DOAS

After retrofit, coal-fired plant SO₂ is below 35 mg/m³ and NOₓ below 50 mg/m³, only about 12–30 ppm by volume. Traditional NDIR or electrochemical methods at this range have strong cross-interference, large drift and slow response.

  • High sensitivity:Sub-ppm detection limit, meeting ultra-low-emission threshold judgment
  • Multi-component:One analyzer measures SO₂, NO, NO₂ (→NOₓ), O₂ and more
  • Strong anti-interference:Differential algorithm auto-removes broad-band absorption of water and dust
  • No consumables, low maintenance:Long-life UV source, no reagents, suited to long online operation

III. DOAS with long optical path cell

The YTG-2000 series combines DOAS with a long-path multi-reflection cell: within a limited volume, the path is extended to hundreds of mm or meters, increasing the absorption signal and thus the low-concentration SNR. With constant-temperature and constant-pressure control, long-term zero and span stability are ensured.

IV. Typical applications

  • Coal-fired / CHP plants:SO₂/NOₓ online monitoring for ultra-low-emission acceptance and routine regulation
  • Industrial boilers & kilns:NOₓ/SO₂ monitoring for sintering, cement and glass kilns
  • Desulfurization/denitrification control:Inlet/outlet comparison to optimize environmental facility operation
  • VOC pretreatment & catalytic monitoring:Extend measured components via UV absorption features

V. Data quality and standards

Per HJ75/HJ76 "Technical specifications for flue gas CEMS (SO₂, NOₓ, particulates)", UV DOAS analyzers need periodic zero/span checks, full-range calibration and comparative monitoring. The YTG-2000 series supports auto-calibration, self-diagnosis and remote maintenance, helping enterprises meet environmental requirements while lowering O&M cost.