I. What is CEMS?

CEMS (Continuous Emission Monitoring System) continuously samples, analyzes, records and transmits flue gas from fixed sources, reflecting in real time the emission levels of SO₂, NOₓ, particulates, flue gas parameters (flow, temperature, pressure, humidity, O₂) and greenhouse gases (CO₂, CH₄, N₂O). It is the core tool for environmental regulation and enterprise self-monitoring.

II. System composition

  • Sampling & pretreatment:Extractive CEMS uses a probe, heated line, condensation dewatering and fine filtration to keep sample gas clean, dry and undistorted
  • Gas analyzer:Multi-component analyzers using IR (GFC/NDIR), UV (DOAS) — the "heart" of the system
  • Flue gas parameters:Velocity/temp/pressure/flow unit and humidity meter for concentration and emission-rate conversion
  • Data acquisition & transmission (DAS):Uploads to the environmental platform via HJ212; supports calibration logs, anomaly flags and data backfill

III. Core standards overview

China has built a fairly complete fixed-source online monitoring standard system; common standard documents are downloadable from the Yantel technical center:

  • HJ75-2017 Technical specification for flue gas CEMS (SO₂, NOₓ, particulates):Specifies CEMS composition, installation, commissioning, acceptance, operation & maintenance and QA
  • HJ76-2017 Requirements and test methods for flue gas CEMS:Specifies technical performance, test conditions and methods — the basis for selection and acceptance
  • HJ212-2017 Data transmission standard for online monitoring systems:Specifies protocol format for data acquisition, transmission and storage
  • GB37822-2019 Emission standard for volatile organic compounds:Sets requirements for VOCs fugitive emission monitoring and control
  • HJ1010-2018 and HJ1013-2018: Cover ambient-air VOCs and GHG monitoring

Download HJ75-2017 (PDF)  |  Download HJ76-2017 (PDF)  |  Download HJ212-2017 (PDF)  |  Download GB37822-2019 (PDF)

IV. Data quality & assurance

HJ75 sets full-lifecycle data-quality requirements:

  • Acceptance test:Zero drift, span drift, response time, indication error, accuracy
  • Routine maintenance:Periodically clean probes, replace filters, check heated-line temperature and condenser drainage
  • Periodic calibration:Auto zero/span calibration and manual comparison; at least one annual reference-method comparison
  • Data validity:Flag and backfill data during calibration/maintenance to keep valid-data rate compliant

V. From CEMS to carbon emission monitoring

As the dual-carbon strategy advances, CO₂, CH₄ and N₂O are gradually included in continuous monitoring, forming an "ordinary pollutants + GHG" integrated trend. Multi-component analyzers based on GFC IR and DOAS UV can meet both environmental and carbon monitoring on one platform, lowering duplicate construction cost.